Wavelet-based coherence analysis of rPPG and PPG signals in time-frequency domain for physiological monitoring
Main Article Content
Abstract
Spectral and time-frequency accuracy of remote photoplethysmography (rPPG) signals must be critically evaluated to bridge the gap with contact PPG measurements, with the aim of improving remote monitoring for low-quality cameras. This study presents a time-frequency coherence analysis based on wavelet transform to assess the synchronization and accuracy between rPPG and PPG signals. Aim of the study is to use continuous wavelet transform (CWT) and wavelet coherence to quantify the time-varying spectral correlation between the two signals. The method identifies dominant frequency bands and phase relationships associated with physiological parameters (e.g., heart rate, respiratory rate), while simultaneously assessing the effects of motion artifacts and environmental noise. Experimental results demonstrate that wavelet coherence provides a robust framework for comparing rPPG and PPG in dynamic scenarios, revealing key insights into signal reliability and potential compensation strategies. Research result improves the understanding of rPPG signal quality and supports its application in wearable devices, telemedicine and remote patient monitoring.
Article Details
References
J. Wang, C. Shan, L. Liu, and Z. Hou, “Camera-based physiological measurement: Recent advances and future prospects,” Neurocomputing, vol. 575, p. 127282, Mar. 2024, doi: 10.1016/j.neucom.2024.127282. DOI: https://doi.org/10.1016/j.neucom.2024.127282
E. Allado et al., “Remote Photoplethysmography Is an Accurate Method to Remotely Measure Respiratory Rate: A Hospital-Based Trial,” JCM, vol. 11, no. 13, p. 3647, Jun. 2022, doi: 10.3390/jcm11133647. DOI: https://doi.org/10.3390/jcm11133647
J. Allen, “Photoplethysmography and its application in clinical physiological measurement,” Physiol. Meas., vol. 28, no. 3, pp. R1– R39, Mar. 2007, doi: 10.1088/0967-3334/28/3/R01.
M. L. Buja and J. Butany, Eds., Cardiovascular pathology, Fifth edition. London: Academic Press, 2022.
International Workshop on Mathematical Methods in Scattering Theory and Biomedical Engineering, Advanced topics in scattering and biomedical engineering: proceedings of the Eighth International Workshop on Mathematical Methods in Scattering Theory and Biomedical Engineering, Lefkada, Greece, 27 -29 September 2007. Singapore, SG: World Scientific, 2008.
X. Liu, J. Fromm, S. Patel, and D. McDuff, “Multi-Task Temporal Shift Attention Networks for On-Device Contactless Vitals Measurement,” 2020, arXiv. doi: 10.48550/ARXIV.2006.03790.
T. Tamura, “Progress of Home Healthcare Sensor in Our Experience: Development of Wearable and Unobtrusive Monitoring,” ABE, vol. 9, no. 0, pp. 189–196, 2020, doi: 10.14326/abe.9.189. DOI: https://doi.org/10.14326/abe.9.189
S. Thupakula, S. S. R. Nimmala, H. Ravula, S. Chekuri, and R. Padiya, “Emerging biomarkers for the detection of cardiovascular diseases,” Egypt Heart J, vol. 74, no. 1, p. 77, Oct. 2022, doi: 10.1186/s43044-022-00317-2. DOI: https://doi.org/10.1186/s43044-022-00317-2
L. Tian et al., “Deep Learning in Biomedical Optics,” Lasers Surg Med, vol. 53, no. 6, pp. 748–775, Aug. 2021, doi: 10.1002/lsm.23414. DOI: https://doi.org/10.1002/lsm.23414
W. Liao, C. Zhang, M. Rosenberger, and G. Notni, “Evaluation of contactless respiratory rate measurement: Thermography vs. rPPG,” Measurement: Sensors, p. 101647, Jan. 2025, doi: 10.1016/j.measen.2024.101647. DOI: https://doi.org/10.1016/j.measen.2024.101647
A. Pai, A. Veeraraghavan, and A. Sabharwal, “HRVCam: robust camera-based measurement of heart rate variability,” J. Biomed. Opt., vol. 26, no. 02, Feb. 2021, doi: 10.1117/1.JBO.26.2.022707. DOI: https://doi.org/10.1117/1.JBO.26.2.022707
H.-W. Chow and C.-C. Yang, “Accuracy of Optical Heart Rate Sensing Technology in Wearable Fitness Trackers for Young and Older Adults: Validation and Comparison Study,” JMIR Mhealth Uhealth, vol. 8, no. 4, p. e14707, Apr. 2020, doi: 10.2196/14707. DOI: https://doi.org/10.2196/14707
H. Rahman, M. U. Ahmed, and S. Begum, “Non-Contact Physiological Parameters Extraction Using Facial Video Considering Illumination, Motion, Movement and Vibration,” IEEE Trans. Biomed. Eng., vol. 67, no. 1, pp. 88–98, Jan. 2020, doi: 10.1109/TBME.2019.2908349. DOI: https://doi.org/10.1109/TBME.2019.2908349
R. Meziati, Y. Benezeth, P. De Oliveira, J. Chappé, and F. Yang, “UBFC-Phys.” IEEE DataPort, Mar. 03, 2021. doi: 10.21227/5DA0-7344.
A. Nakonechnyi and I. Berezhnyi, “Estimation of Heart Rate and its Variability Based on Wavelet Analysis of Photoplethysmographic Signals in Real Time,” in 2023 IEEE 12th International Conference on Intelligent Data Acquisition and Advanced Computing Systems: Technology and Applications (IDAACS), Dortmund, Germany: IEEE, Sep. 2023, pp. 765–769. doi: 10.1109/IDAACS58523.2023.10348785. DOI: https://doi.org/10.1109/IDAACS58523.2023.10348785
P. Du, W. A. Kibbe, and S. M. Lin, “Improved peak detection in mass spectrum by incorporating continuous wavelet transform-based pattern matching,” Bioinformatics, vol. 22, no. 17, pp. 2059–2065, Sep. 2006, doi: 10.1093/bioinformatics/btl355. DOI: https://doi.org/10.1093/bioinformatics/btl355
I. Berezhnyi and A. Nakonechnyi, “Multiresolution analysis of poor remote photoplethysmography signal using wavelet transform,” in CEUR Workshop Proc., CEUR-WS, 2024, pp. 57–72. [Online]. Available: https://www.scopus.com/inward/record.uri?eid=2-s2.0-85215781423&partnerID=40&md5=7a324b3194e1ff39b679b3a4efb7aa98
J. Allen, “Photoplethysmography and its application in clinical physiological measurement,” Physiol. Meas., vol. 28, no. 3, pp. R1– R39, Mar. 2007, doi: 10.1088/0967-3334/28/3/R01. DOI: https://doi.org/10.1088/0967-3334/28/3/R01
P. A. Kyriacou and J. Allen, Eds., Photoplethysmography: technology, signal analysis and applications. London: Elsevier Academic Press, 2022.